Finished shoes anti-aging how to test
Testing Purposes: This test is conducted to evaluate the aging resistance of shoes under controlled conditions. The objective is to simulate long-term exposure to heat and determine how well the materials and structure of the shoes withstand such stress. Test Range: The test applies to various types of shoes, including but not limited to athletic shoes, casual footwear, and formal wear. Test Equipment: The testing is performed using a GX-3010 Aging Chamber, which allows for precise control of temperature and humidity during the aging process. Test Conditions: The aging chamber is maintained at a constant temperature of 70°C throughout the test duration. Parameter Requirements: 1. Test Temperature: 70°C 2. Test Duration: 120 hours Shoe Aging Test Procedure: 1. Turn on the aging chamber and set the temperature to 70°C. 2. Once the chamber reaches the desired temperature, place the test samples (one sample should be kept as a control) inside the chamber and set the timer for 120 hours. 3. After the test period is complete, open the aging chamber and carefully remove the samples. 4. Compare the aged samples with the original control sample. Observe any changes in color, texture, or structural integrity. The results are evaluated based on Li Ning's internal standards. Result Evaluation: If the aged sample shows signs of discoloration, fading, cracking, peeling, frost formation, or any other abnormal condition compared to the original sample, it is considered unacceptable. Additional Tips for Shoe Care and Maintenance: Fresh Bowl,Customized Sizes Fresh Bowl,Crack Resistant Preservation Bowl,Reusable Porcelain Fresh Bowl shaoxing qinzi business company ltd , https://www.qinzisx.com